GC-WSCD 系列水冷螺桿式冷水機組主要技術參數(shù)表
注 ■ 制冷量標定工況:冷凍水進水溫度12℃,出水溫度7℃,冷卻水進水溫度30℃,出水溫度35℃。
■ 允許電壓波動±10%。
■ 冷凍水、冷卻水進出水溫與條件不一致時,請參考參數(shù)修正表。
■ 簡明計算公式 Compendious Calculating Formula
■ 蒸發(fā)器的凍水流量(升/秒)= 機組制冷量(KW)÷(進出冷凝器的凍水溫升度數(shù)(℃)×4.187)
■ 蒸發(fā)器的凍水流量(升/秒)= 機組總排熱量(KW)÷(進出冷凝器的凍卻水溫升度數(shù)(℃)×4.187)
■ Flow of Freezing Water in Evaporator=Cooling Capacity from the Unit/
Temperature Difference of Freeing Water Flowing ln/Out the Evaporator
■ Flow of Freezing Water in Condenser=Quantity of Heat Elimination form the Unit/
Temperature Difference of Freezing Water Flowing in/Out The Evaoorator
技術參數(shù) Technique Parameters
GC-WSCD 系列水冷螺桿式冷水機組主要技術參數(shù)表
注■ 除表列產(chǎn)品型號外,我公司歡迎用戶提出不同需求,進行新的選型和制造,我公司保留對產(chǎn)品設計及規(guī)格的更改而無需通知的權利。
■ Besides the listed products,we can meet different requirements of users by selecting and manufacturing new types of products.We have the right to change the design and specifications without notice you..
■ 制冷技術中常用單位的換算 Unit Conversion in Common Use In Cooling Techniques
■ 1馬力(或1匹馬功率)=735.5瓦(w)=0.7355千瓦(kw)
■ 1千卡/小時(kcal/h)=1.163瓦(w)
■ 1美國冷噸=3024千卡/小時(kcal/h)=3.517千瓦(kw)
■ 1日本冷噸=3320千卡/小時(kcal/h)=3.861千瓦(kw)
■ 攝氏溫度℃=(華氏溫度F-32)5/9(注:1冷噸就是使1噸0℃的水在24小時內變?yōu)?℃的冰所需要的制冷量。)
■ 1Horsepower=735.5(w) =0.7355(kw)
■ 1(kcal/h)=1.163(w)
■ 1American Cooling Ton=3024(kcal/h)=3.517(kw)
■ 1Japanese Cooling Ton =3320(kcal/h)=3.861(kw)
■ Centigrade℃=(Fahrenheit F-32)5/9
(One cooling ton refers to the required cooling quantity when one ton of water in 0℃ turns to ice in 0℃)
技術參數(shù) Technique Parameters
GC-WSCD 系列水冷螺桿式冷水機組主要技術參數(shù)表
技術參數(shù) Technique Parameters
GC-WSCD 系列水冷螺桿式冷水機組主要技術參數(shù)表