聯(lián)系電話
參考價(jià): | 面議 |
- 美國(guó)戴安 P/N: 064312 產(chǎn)品型號(hào)
- 品牌
- 代理商 廠商性質(zhì)
- 上海 所在地
訪問次數(shù):8更新時(shí)間:2022-05-31 11:40:03
- 聯(lián)系人:
- 李經(jīng)理
- 電話:
- 021-/67610176
- 手機(jī):
- 13120725556
- 傳真:
- 021-67618321
- 地址:
- 上海市松江區(qū)淶寅路1025號(hào)3002室
- 網(wǎng)址:
- www.xiyanlab.com
掃一掃訪問手機(jī)商鋪
Acclaim Explosives LC Column
Acclaim Explosives Columns: A Total Solution for EPA Method 8330
The Thermo Scientific Acclaim? Explosives E1 (5 ?m) and E2 (5, 3 and 2.2 μm) silica-based reversed-phase columns are designed to resolve all 14 explosives listed in EPA SW-846 Method 8330: Nitroaromatics and Nitramines by HPLC. Their unique chemistries deliver superior resolution with complementary selectivities. The E1 is recommended for use as a direct replacement for ODS columns for the primary analysis.The E2 may be used as either a primary or a confirmatory column.
- Two column chemistries, each offering baseline resolution of all 14 compounds targeted by EPA Method 8330
- Mutually-complementary selectivity
- Simple, isocratic elution conditions
- Rugged columns with good lot-to-lot reproducibility
- Unique selectivities for separating other nitroaromatic molecules
The Acclaim Explosives stationary phases are based on ultrahigh-purity spherical silica gel particles, with 120 ? pore size. The Acclaim Explosives E1 is available in a 5 ?m particle size and E2 columns are available in 5, 3 and 2.2 μm particle sizes. The unique chemistry of these columns offers exceptional selectivity and stability over the range of pH 3.0 to 7.0, and their design ensures good column life and easy cleanup.
While both columns perform reproducibly under their optimized conditions, separation conditions for the Acclaim Explosives E2 can be readily changed to accommodate inclusion of additional explosives compounds.
The manufacturing process is controlled to ensure that every Explosives column delivers reproducible performance, lot-to-lot and column-to-column. The columns are tested for baseline resolution of all 14 explosives.
技術(shù)參數(shù):
Acclaim Explosives Columns — A Total Solution for EPA Method 8330 Specifications | |
---|---|
Starting Material | Ultra-pure silica |
Particle Size | 3 ?m and 5 ?m |
Particle Shape | Spherical |
Particle Size Distribution (40/90) | < 1.3 |
Metal Impurity (Na, Fe, Al) | <10.0 ppm Total Metal < 3.0 ppm Individual Metals |
Pore Volume | 0.9 - 1.0 mL/g |
Average Pore Diameter | 120 ? |
Surface Area | 300 m2/g |
Recommended pH range | 3.0 - 7.0 |
Temperature Limit | 50 oC |
訂購(gòu)信息:
Analytical Columns | |
---|---|
Acclaim RSLC Explosives E2, 2.2?m Analytical (2.1 x 100mm) | 076225 |
Acclaim RSLC Explosives E2, 2.2?m Analytical (2.1 x 150mm) | 076226 |
Acclaim RSLC Explosives E2, 2.2?m Analytical (3.0 x 100mm) | 076227 |
Acclaim Explosive E2, 3 ?m, Analytical, (2.1 x 150 mm) | 070083 |
Acclaim Explosive E2, 3 ?m, Analytical, (3.0 x 150 mm) | 070082 |
Acclaim Explosive E2, 3 ?m, Analytical, (3.0 x 250 mm) | 070081 |
Acclaim Explosives E1 (4.6 x 250 mm) | 064305 |
Acclaim Explosives E2 (4.6 x 250 mm) | 064309 |
Acclaim Explosives Kit (includes 064305, 064309, 064303, 064307; requires holder 059456) | 064312 |
Guard Columns | |
---|---|
Acclaim Explosives E1, 5 ?m Guard Cartridges, (4.6 x 10 mm), 2 ea (use V-2 Holder) | 069702 |
Acclaim E2, 5?m Guard Cartridges (3 x 10mm), 2ea, requires holder 069580 | 071989 |
Acclaim Explosives E2, 5 ?m Guard Cartridges, (4.6 x 10 mm), 2 ea (use V-2 Holder) | 069703 |
Acclaim SST Guard Cartridge Holder V-2 | 069580 |
Acclaim Guard Kit (Holder and coupler) V-2 | 069707 |
Guard to Analytical Column Coupler V-2 | 074188 |
Acclaim Explosive E1 Guard (4.3 x 10 mm), 2 ea; requires holder 059456 | 064303 |
Acclaim Explosive E2 Guard (4.3 x 10 mm), 2ea; requires holder 059456 | 064307 |
Acclaim SST Guard Cartridge Holder V-1 | 059456 |
Guard to Analytical Column Coupler | 059457 |
Guard Kit (Holder and Coupler) | 059526 |