您好, 歡迎來(lái)到興旺寶! 登錄| 免費(fèi)注冊(cè)| 產(chǎn)品展廳| 收藏商鋪|
當(dāng)前位置:深圳市銀飛電子科技有限公司>>其它檢測(cè)儀器>>其它檢測(cè)儀表>> 福祿克5960A Triple Point of Argon System
福祿克5960A Triple Point of Argon System
The Fluke Calibration 5960A Triple Point of Argon System enables primary standards laboratories to realize the argon triple point using a consistent, reproducible process with the lowest uncertainty of any commercially available system. The Fluke Calibration system produces a 30-hour temperature plateau and provides multiple entrant wells to increase SPRT calibration efficiency and throughput.
A number of technology advancements are designed into the Fluke Calibration 5960A system to achieve a low uncertainty of 0.25 mK. For example, the argon cell is carefully built with an ultra-clean process using 99.9999 % (six nines) purity argon resulting in an uncertainty factor from impurities of 0.015 mK. The deep, 480 mm immersion depth of the entrant well minimizes the effects of stem conduction to less than 0.01 mK and radial uniformity to less than 0.05 mK.
The 5960A system utilizes liquid nitrogen (LN2) in a Dewar vessel surrounding an argon cell to achieve –189.3442 °C. A digital controller combined with a heater maintains a temperature plateau lasting up to 30 hours with 0.1 mK variation without using complicated pressure controls. By regular renewal of liquid nitrogen in the system, the plateau length can even be extended to four days. The system’s long, stable temperature plateau lets you carry out your SPRT calibrations with better quality and more efficiency. Four entrant wells increase lab productivity by allowing you to calibrate four SPRTs simultaneously.
The display panel of the 5690A provides a simple menu structure with soft function keys for setup and programming the argon system. The readout displays simultaneously the set-point temperature, actual control sensor temperature and percent heater power. The display is selectable in eight languages—English, French, Spanish, Italian, German, Russian, Chinese, and Japanese. Applying positive pressure with helium or dry nitrogen to an entrant well port prevents your SPRTs from being bound in the entrant well by freezing moisture. You can insert and remove SPRTs as desired from the system over the duration of a single plateau. Other systems require that you first melt the cell in order to add or remove an SPRT.
Specifications | |
Assigned value | -189.3442 °C |
Argon gas purity | 99.9999 % (6N purity) |
Uncertainty (k=2) | 0.25 mK |
Length of plateau (0.1 mK) | >30 hours |
Argon cell depth* | 160 mm |
Number of entrant wells | 4 |
Radial uniformity | 0.05 mK |
Total immersion depth | 480 mm |
Entrant well inner diameter (ID) | 8.0 mm |
Argon gas volume | 13.4 moles (535 grams) |
Liquid nitrogen Dewar volume | 44.2 liters |
Display resolution | 0.001 °C |
Set-point accuracy | 0.1 °C (adjustable) |
Power requirements | 100 V to 115 V (± 10 %) 50/60 Hz, 230 W 230 V (± 10 %) 50/60 Hz, 230 W |
System fuse ratings | 115 V: 2 A T 250 V 230 V: 1 A T 250 V |
Size (HxD) | 952 mm x 673 mm x 483 mm (37.5 in x 26.5 in x 19 in) |
Weight | 94 kg (207 lbs) |
*Measured from the bottom of the probe well to the surface of argon sample |
該產(chǎn)品由深圳市銀飛電子科技有限公司提供,銷售商地址位于廣東省深圳市福田區(qū)華強(qiáng)北路群星廣場(chǎng)A座22樓2217。請(qǐng)您仔細(xì)閱讀產(chǎn)品使用說(shuō)明書,正確使用。
如果想試用該產(chǎn)品,請(qǐng)以下單位:
銀飛電子主要銷售通信設(shè)備、儀器儀表、電力設(shè)備、熱工儀表、校準(zhǔn)設(shè)備及工具配件。
請(qǐng)輸入賬號(hào)
請(qǐng)輸入密碼
請(qǐng)輸驗(yàn)證碼
以上信息由企業(yè)自行提供,信息內(nèi)容的真實(shí)性、準(zhǔn)確性和合法性由相關(guān)企業(yè)負(fù)責(zé),興旺寶對(duì)此不承擔(dān)任何保證責(zé)任。
溫馨提示:為規(guī)避購(gòu)買風(fēng)險(xiǎn),建議您在購(gòu)買產(chǎn)品前務(wù)必確認(rèn)供應(yīng)商資質(zhì)及產(chǎn)品質(zhì)量。