深圳市銀飛電子科技有限公司
初級會員 | 第1年

18923421799

當前位置:深圳市銀飛電子科技有限公司>>其它檢測儀器>>其它檢測儀表>> LTCM-500材料力學測試臺

LTCM-500材料力學測試臺

參  考  價面議
具體成交價以合同協(xié)議為準

產品型號

品       牌

廠商性質代理商

所  在  地深圳市

更新時間:2022-05-05 16:10:02瀏覽次數:5次

聯系我時,請告知來自 興旺寶
同類優(yōu)質產品更多>
LTCM-500材料力學測試臺
在使用LTCM系列閱讀說明書*。按照本手冊中的說明,Z佳的精度和性能可以達到。不要用蓋從LTCM系列術前驗證輸入電源。*資本管理公司的系列開關電源。該測試儀采用115V或230V電源輸入模塊提供了相應的源動力的合理設置。始終確保電源功率匹配在開機前的電源輸入模塊的設置。不這樣做,可能會導致嚴重損壞測試儀。

LTCM-500材料力學測試臺

Declaration of Conformity

A sample of this product has been accessed against the essential health and safety requirements of the Low Voltage and the EMC Directives listed. Based on conformity with the listed directives, this product is deemed in compliance with the following:
 - BS EN 61010-1:2010 Safety Requirements for Electrical Equipment
 - BS EN 61326-1:2006 Electrical equipment for measurement, control and laboratory use; General Requirements

Precautions

? Read the instruction manual compley before attempting to use the LTCM Series. By following the instructions contained in this manual, the optimum accuracy and performance can be attained.Never operate the LTCM Series with the cover off.Verify Input Power Source BEFORE operation. The LTCM Series has a switchable power supply. The tester may operate with 115V or 230V provided the Power Input Module is in the proper setting corresponding to the source power. Always make sure that the supply power matches the setting on the Power Input Module before turning power ON. Failure to do so may cause serious damage to the tester.LTCM-500材料力學測試臺
? The LTCM Series has a moving crosshead! Exercise extreme caution during testing or whenever the crosshead is moving. Never place 
fingers inside the column.
? Use Chatillon force gauges. The LTCM Series is designed to be used safely with the Chatillon force gauges listed in this manual.
? Class 1 product must be connected to a mains socket outlet with a protective earth connection.
? Place LTCM Series so that it is easy to access the power cord.
? Never use the LTCM Series in a manner not specified by AMETEK.
? Only use safety approved power cords that are supplied with the LTCM Series test machines.

Precautions

? Read the instruction manual compley before attempting to use the LTCM Series. By following the instructions contained 
in this manual, the optimum accuracy and performance can be attained.
? Never operate the LTCM Series with the cover off.
? Verify Input Power Source BEFORE operation. The LTCM Series has a switchable power supply. The tester may operate with 115V or 
230V provided the Power Input Module is in the proper setting corresponding to the source power. Always make sure that the supply power matches the 
setting on the Power Input Module before turning power ON. Failure to do so may cause serious damage to the tester.
? The LTCM Series has a moving crosshead! Exercise extreme caution during testing or whenever the crosshead is moving. Never place 
fingers inside the column.
? Use Chatillon force gauges. The LTCM Series is designed to be used safely with the Chatillon force gauges listed in this manual.
? Class 1 product must be connected to a mains socket outlet with a protective earth connection.
? Place LTCM Series so that it is easy to access the power cord.
? Never use the LTCM Series in a manner not specified by AMETEK.
? Only use safety approved power cords that are supplied with the LTCM Series test machines.

Precautions

? Read the instruction manual compley before attempting to use the LTCM Series. By following the instructions contained 
in this manual, the optimum accuracy and performance can be attained.
? Never operate the LTCM Series with the cover off.
? Verify Input Power Source BEFORE operation. The LTCM Series has a switchable power supply. The tester may operate with 115V or 
230V provided the Power Input Module is in the proper setting corresponding to the source power. Always make sure that the supply power matches the 
setting on the Power Input Module before turning power ON. Failure to do so may cause serious damage to the tester.
? The LTCM Series has a moving crosshead! Exercise extreme caution during testing or whenever the crosshead is moving. Never place 
fingers inside the column.
? Use Chatillon force gauges. The LTCM Series is designed to be used safely with the Chatillon force gauges listed in this manual.
? Class 1 product must be connected to a mains socket outlet with a protective earth connection.
LTCM-500力學測試臺

? Place LTCM Series so that it is easy to access the power cord.
? Never use the LTCM Series in a manner not specified by AMETEK.
? Only use safety approved power cords that are supplied with the LTCM Series test machines.

Console Overview
The LTCM Series provides these functions on the tester’s console:
? On/Off Switch  

? Emergency Stop Switch
? Speed Units of Measure Selector Switch
? Speed Selector Knob
? Return Speed Switch
? Crosshead Direction of Travel Switch
? LED Display
? Speed Units Indicator

該產品由深圳市銀飛電子科技有限公司提供,銷售商地址位于廣東省深圳市福田區(qū)華強北路群星廣場A座22樓2217。請您仔細閱讀產品使用說明書,正確使用。

如果想試用該產品,請以下單位: 

銀飛電子主要銷售通信設備、儀器儀表、電力設備、熱工儀表、校準設備及工具配件。

會員登錄

×

請輸入賬號

請輸入密碼

=請輸驗證碼

收藏該商鋪

X
該信息已收藏!
標簽:
保存成功

(空格分隔,最多3個,單個標簽最多10個字符)

常用:

提示

X
您的留言已提交成功!我們將在第一時間回復您~
撥打電話
在線留言