Floating Roof Tanks - Spill Prevention Overview Specifically designed for Floating Roof Tanks (Internal and External roofs) with Flexible Sensing Element 700-0005-594 進(jìn)口射頻導(dǎo)納物位開關(guān)Floating Roof Tanks - Field Adjustable lengths from 1' to 18' (0.3 to 5.48 m) 12" to 216" (305mm to 5486 mm)
- Wetted Parts: 316SS 3/4" NPT Mounting, 3/16" FEP insulated flexible and adjustable cable, Non-Sparking Brass Sensor.
Features: - Alarm trip points with any contact of internal or external roof.
- Alarm trip points in "Sunken Roof" applications with less than 1" product.
- One system will fit most floating roof tank application needs, reducing field spares.
Inligent Electronics - Meets API 2350 regulations.
- For use in safety related systems with requirements for functional safety for SIL2 (SIL 3 with Redundant Switch) In accordance to IEC61508-2, Sec. 7.4.3.1 1999 (Conforms to SIL, FMEDA Requirements - Exida)
- No calibration or setpoint adjustments.
- Automatically recognizes and ignores coatings to prevent false alarms.
- Continuous Self-Test monitors circuits and sensing elements for faults
- Remote or Integral Electronics
? Dual Compartment Housing The dual compartment housing separates the customer wiring from the sensing element and operating circuits. The encapsulated power supply/terminal block design eliminates the� possibility of damage caused by moisture in the conduit. Self-Test Feature Automatic and Local or Remote Manual test functions ensure proper system operation. Auto Verification Each InliPoint is supplied with a continuous self-test feature that constantly monitors the integrity of not just the electronics, but the sensing element and interconnecting cable. If a fault is detected, the InliPoint Auto Verification feature alerts plant personnel. Manual Certification The InliPoint provides a method to manually test the entire system without removing the sensor from the tank. The Manual Certify Test checks that the Auto Verify circuits are operating and confirms the probe and cables are properly connected. The Manual Certify also allows the InliPoint electronics to sense changes in the probe that simulate contact with the media or a floating roof. This provides the user with a method to insure working performance without having to climb the tank. At the completion of the Certify test routine, the output is momentarily held in the alarm state so personnel can confirm that the control circuits connected to the Final Control Element are functioning properly. Technology: RF Admittance
Calibration: None
Modes Of Operation: High and Low Level
Repeatability: 2 mm (0.08 inch) conductive liquids
Response Time: Less than one second
Ambient Elctronic Temperature: -40 to 70°C (-40 to 158°F)
Storage Temperature: -40 to 85°C (-40 to 185°F)
Indicators: LEDs: Green Power, Red Alarm
Self-Check: AutoVerify automatically and continuously checks electronics and sensing element for faults. Manual Certify checks that the AutoVerify circuits are functioning.
Time Delay: 0-60 seconds, forward or reverse-acting
Supply Voltage: 13-30 Vdc
Power Consumption: 2 watts maximum
Output: 8mA - Alarm 8mA - Normal 16mA - Normal 16mA - Alarm 22mA - Fault 5mA - Fault
Housing: Dual Compartment, Powder- Coated aluminum with two cable entries
Cable Entry: M20 x 1.5 CENELEC 3/4-inch NPT FM/CSA
Ingress Protection: IP66 NEMA 4X 該產(chǎn)品由深圳市銀飛電子科技有限公司提供,銷售商地址位于廣東省深圳市福田區(qū)華強(qiáng)北路群星廣場A座22樓2217。請您仔細(xì)閱讀產(chǎn)品使用說明書,正確使用。 如果想試用該產(chǎn)品,請以下單位: 銀飛電子主要銷售通信設(shè)備、儀器儀表、電力設(shè)備、熱工儀表、校準(zhǔn)設(shè)備及工具配件。 |