介電常數(shù)與介質(zhì)損耗測定儀工作特性
1.Q值測量
a.Q值測量范圍:2~1023;
b.Q值量程分檔:30、100、300、1000、自動換檔或手動換檔;
c.標(biāo)稱誤差
A | C | |
頻率范圍 | 25kHz~10MHz | 100kHz~10MHz |
固有誤差 | ≤5%±滿度值的2% | ≤5%±滿度值的2% |
工作誤差 | ≤7%±滿度值的2% | ≤7%±滿度值的2% |
頻率范圍 | 10MHz~60MHz | 10MHz~160MHz |
固有誤差 | ≤6%±滿度值的2% | ≤6%±滿度值的2% |
工作誤差 | ≤8%±滿度值的2% | ≤8%±滿度值的2% |
2.電感測量范圍
A | C |
14.5nH~8.14H | 4.5nH~140mH |
3.電容測量
A | C | |
直接測量范圍 | 1~460p | 1~205p |
主電容調(diào)節(jié)范圍 | 40~500pF | 18~220pF |
準(zhǔn)確度 | 150pF以下±1.5pF; 150pF以上±1% | 150pF以下±1.5pF 150pF以上±1% |
注:大于直接測量范圍的電容測量見使用方法。
4.信號源頻率覆蓋范圍
| A | C |
頻率范圍 | 10kHz~60MHz | 0.1~160MHz |
CH1 | 10~99.9999kHz | 0.1~0.999999MHz |
CH2 | 100~999.999kHz | 1~9.99999MHz |
CH3 | 1~9.99999MHz | 10~99.9999MHz |
CH4 | 10~60MHz | 100~160MHz |
頻率指示誤差 | 3×10-5±1個字 |
5.Q合格指示預(yù)置功能:預(yù)置范圍:5~1000
6.Q表正常工作條件
a. 環(huán)境溫度:0℃~+40℃;
b.相對濕度:<80%;
c.電源:220V±22V,50Hz±2.5Hz。
7.其他
a.消耗功率:約25W;
b.凈重:約7kg;
c.外型尺寸:(寬×高×深)mm:380×132×280。
介電常數(shù)與介質(zhì)損耗測定儀使用時的注意事項
1、試驗過程中不能讓無關(guān)人員靠近,因本試驗儀器可產(chǎn)生較高的電壓,未經(jīng)過培訓(xùn)的人員不能使用該設(shè)備。試驗時要有監(jiān)護(hù)人員,不要單人使用。以防萬一發(fā)生意外情況。
2、長時間不使用設(shè)備,在再使用時,先讓儀器空載加壓一次,即把高壓電極的接線從均壓球上取下。查看計算機(jī)試驗界面,看看高壓電壓是否正常。
3、試驗中發(fā)生意外情況要及時切斷電源,問題處理后才能繼續(xù)試驗。
4、設(shè)備安放要平穩(wěn),安放的地面要堅固。是水泥地面以免產(chǎn)生共振。
5、該設(shè)備在使用中外殼要接保護(hù)地線,既設(shè)備外殼接大地,以保護(hù)操作人員和設(shè)備運行的安全。
6、使用完設(shè)備后,要關(guān)掉系統(tǒng)各部分電源,不準(zhǔn)帶電插拔電源線。
7、要按規(guī)定的電源電壓接入設(shè)備。確保電路接線正確。否則會損壞設(shè)備。
8、該儀器需安置在室內(nèi),實驗室應(yīng)整潔、干燥、無腐蝕性介質(zhì),非相人員不要隨意操作。
9、不要讓設(shè)備電纜碰到尖邊,以免劃破電纜絕緣;不要讓電纜壓在重物之下,以免壓斷電纜引起火災(zāi);不要用電纜拉物體或用電纜捆綁物體,以免拉斷電纜使設(shè)備不能正常運轉(zhuǎn)。
10、不要讓設(shè)備碰到水濺,腐蝕性氣體,可燃?xì)怏w和可燃物。如果不避免,可能火災(zāi)。
11、搬動設(shè)備時,要切斷設(shè)備電源,既要把插頭從插座中拔下。禁止搬動設(shè)備時放倒設(shè)備或傾斜45°角以上。
12、不要在設(shè)備運行時插拔設(shè)備的電源插頭。
特點:
◎ 本公司創(chuàng)新的自動Q值保持技術(shù),使測Q分辨率至0.1Q,使tanδ分辨率至0.00005 。
◎ 能對固體絕緣材料在10kHz~120MHz介質(zhì)損耗角(tanδ)和介電常數(shù)(ε)變化的測試。
◎ 調(diào)諧回路殘余電感值低至8nH,保證100MHz的(tanδ)和(ε)的誤差較小。
◎ 特制LCD屏菜單式顯示多參數(shù):Q值,測試頻率,調(diào)諧狀態(tài)等。
◎ Q值量程自動/手動量程控制。
◎ DPLL合成發(fā)生1kHz~60MHz, 50kHz~160MHz測試信號。獨立信號 源輸出口,所以本機(jī)又是一臺合成信號源。
◎ 測試裝置符合國標(biāo)GB/T 1409-2006,美標(biāo)ASTM D150以及IEC60250規(guī)范要求。
電感器:
按測試頻率要求,需要配置不同量的電感器。
例如:在1MHz測試頻率時,要配250μH電感器,在50MHz測試頻率時,要配0.1μH電感器等。
高頻介質(zhì)樣品(選購件):
在現(xiàn)行高頻介質(zhì)材料檢定系統(tǒng)中,檢定部門為高頻介質(zhì)損耗測量儀提供的測量標(biāo)準(zhǔn)是高頻標(biāo)準(zhǔn)介質(zhì)樣品。
該樣品由人工藍(lán)寶石,石英玻璃,氧化鋁陶瓷,聚四氟乙烯,環(huán)氧板等材料做成Φ50mm,厚1~2mm測試樣品。用戶可按需訂購,以保證測試裝置的重復(fù)性和準(zhǔn)確性。
工作頻率范圍是10kHz~120MHz,它能完成工作頻率內(nèi)材料的高頻介質(zhì)損耗角(tanδ)和介電常數(shù)(ε)變化的測試。
本儀器中測試裝置是由平板電容器和測微圓筒線性電容器組成,平板電容器一般用來夾被測樣品,配用Q表作為指示儀器。
絕緣材料的損耗角正切值是通過被測樣品放入平板電容器和不放樣品的Q值變化和厚度的刻度讀數(shù)通過公式計算得到。
同樣,由測微圓筒線性電容器的電容量讀數(shù)變化,通過公式計算得到介電常數(shù)。
主要技術(shù)指標(biāo):
2.1 tanδ和ε性能:
2.1.1 固體絕緣材料測試頻率10kHz~120MHz的tanδ和ε變化的測試。
2.1.2 tanδ和ε測量范圍:
tanδ:0.1~0.00005,ε:1~50
2.1.3 tanδ和ε測量精度(1MHz):
tanδ:±5%±0.00005,ε:±2%
工作頻率范圍:50kHz~50MHz 四位數(shù)顯,壓控振蕩器
Q值測量范圍:1~1000三位數(shù)顯,±1Q分辨率
可調(diào)電容范圍:40~500 pF ΔC±3pF
電容測量誤差:±1%±1pF
Q表殘余電感值:約20nH
裝置:
2.3.1 平板電容器極片尺寸::Φ38mm和Φ50mm二種.
2.3.2 平板電容器間距可調(diào)范圍和分辨率:0~8mm, ±0.01mm
2.3.3 圓筒電容器線性: 0.33 pF /mm±0.05 pF,
2.3.4 圓筒電容器可調(diào)范圍:±12.5mm(±4.2pF)
2.3.5 裝置插頭間距:25mm±0.1mm
2.3.6 裝置損耗角正切值:≤2.5×10-4
北廣電性能及橡膠塑料常用儀器
*材料試驗機(jī)(電子*,金屬材料,非金屬材料,管材,高低溫,液壓伺服*試驗機(jī))
電壓擊穿試驗儀(介電擊穿強(qiáng)度,固體絕緣材料電氣介電強(qiáng)度試驗機(jī))
體積表面電阻率測定儀(可測試固體液體膏體粉末材料)
碳素材料電阻率測試儀
電線電纜導(dǎo)體半導(dǎo)體材料電阻率測試儀
橡膠塑料滑動摩擦試驗機(jī)(國標(biāo),非國標(biāo),可定制)
介電常數(shù)介質(zhì)損耗測試儀(可測試固體液體)
學(xué)校介電常數(shù)介質(zhì)損耗測試儀
高頻介電常數(shù)介質(zhì)損耗測試儀
工頻介電常數(shù)介質(zhì)損耗測試儀
絕緣材料耐電弧性能試驗儀
液顯熱變形維卡軟化點溫度測定儀
計算機(jī)控制熱變形維卡溫度試驗機(jī)
塑料球壓痕硬度計
熔體流動速率測定儀/熔融指數(shù)儀
計算機(jī)控制馬丁耐熱試驗儀
產(chǎn)品保修售后服務(wù)承諾:
一、安裝調(diào)試:協(xié)助試驗機(jī)的安裝,負(fù)責(zé)試驗機(jī)的運輸、調(diào)試。
二、驗收標(biāo)準(zhǔn):試驗機(jī)按訂貨技術(shù)附件進(jìn)行驗收。終驗收在買方進(jìn)行,對用戶提供的試樣進(jìn)行試驗,并提供測試報告。
三、培訓(xùn):安裝調(diào)試同時,在儀器操作現(xiàn)場一次性免費培訓(xùn)操作人員2-3名,該操作人員應(yīng)是由需方選派的*穩(wěn)定的員工,培訓(xùn)后能夠?qū)υO(shè)備基本原理、軟件使用、操作、維護(hù)事項理解和應(yīng)用,使人員能夠獨立操作設(shè)備對樣品進(jìn)行檢測、分析,同時能進(jìn)行基本的維護(hù)。
四、軟件升級:終生免費提供新版本控制軟件。
五、保修:
1、設(shè)備保修兩年,終身售后服務(wù),一年內(nèi)非人為損壞的零部件免費更換,保修期內(nèi)接到用戶邀請后,zui遲響應(yīng)時間為2小時內(nèi),在與用戶確認(rèn)故障后,我公司會在48小時內(nèi)派工程師到達(dá)現(xiàn)場進(jìn)行免費服務(wù),盡快查清故障所在位置和故障原因,并向用戶及時報告故障的原因和排除辦法。
2、保修期內(nèi)人為損壞的零部件按采購(加工)價格收費更換。
3、保修期外繼續(xù)為用戶提供優(yōu)質(zhì)技術(shù)服務(wù),在接到用戶維修邀請后3天內(nèi)派工程師到達(dá)用戶現(xiàn)場進(jìn)行維修。并享有優(yōu)惠購買零配件的待遇?!?/span>
4、傳感器過載及整機(jī)電路超壓損壞不在保修范圍內(nèi)。
六、售后管理:
我公司實現(xiàn)計算機(jī)化管理,實行客戶定期回訪制度,定期復(fù)查設(shè)備的工作情況,定期指導(dǎo)用戶對設(shè)備進(jìn)行保養(yǎng)和檢測,以便設(shè)備正常運轉(zhuǎn),跟蹤客戶的設(shè)備使用情況,以便及時對設(shè)備進(jìn)行維護(hù)
The working characteristics of dielectric constant and dielectric loss detector
1.Q measurement
A.Q range: 2 ~ 1023;
B.Q range profile: 30, 100, 300, 1000, automatic shift or manual shift;
C. nominal error
A
C
Range of frequency
25kHz ~ 10MHz
100kHz ~ 10MHz
Inherent error
Full scale value is less than or equal to 5% + 2%
Full scale value is less than or equal to 5% + 2%
Working error
Full scale value is less than or equal to 7% + 2%
Full scale value is less than or equal to 7% + 2%
Range of frequency
10MHz ~ 60MHz
10MHz ~ 160MHz
Inherent error
Full scale value is less than or equal to 6% + 2%
Full scale value is less than or equal to 6% + 2%
Working error
Full scale value is less than or equal to 8% + 2%
Full scale value is less than or equal to 8% + 2%
2 inductance measurement range
A
C
14.5nH ~ 8.14H
4.5nH ~ 140mH
3 capacitance measurement
A
C
Direct measurement range
1 ~ 460p
1 ~ 205p
Main capacitance range
40 ~ 500pF
18 ~ 220pF
Accuracy
150pF + 1.5pF;
150pF 1%
150pF + 1.5pF
150pF 1%
Note: the method of measuring the capacitance of the capacitance measuring range is greater than the direct measurement range.
4 signal source frequency coverage
A
C
Range of frequency
10kHz ~ 60MHz
0.1 ~ 160MHz
CH1
10 ~ 99.9999kHz
0.1 ~ 0.999999MHz
CH2
100 ~ 999.999kHz
1 ~ 9.99999MHz
CH3
1 ~ 9.99999MHz
10 ~ 99.9999MHz
CH4
10 ~ 60MHz
100 ~ 160MHz
Frequency indicating error
3 x 10-5 1 words
5.ualified preset function: preset range: 5 ~ 1000
6.Q normal working condition
A. environment temperature: 0 C ~ +40;
B. relative humidity: <80%;
C. power supply: 220V + 22V, 50Hz + 2.5Hz.
7 other
A. power consumption: about 25W;
B. net weight: About 7kg;
C. appearance size: (wide x x x x x x 280) mm:380 x 132.
The attention of the dielectric constant and the dielectric loss meter
1, the test process can not let the unrelated persons close, because this test instrument can produce a higher voltage, without the trained personnel can not use the equipment. When the test must have the guardian, not single use. In case of accident..
2, a long time without the use of equipment, in the re-use, the first instrument no-load pressure once, that the high-voltage electrode wiring from the pressure ball. Check the computer test interface to see if the high voltage is normal..
3, the accident occurred in the test to cut off the power, the problem can continue to test the problem.
4, the device is placed smoothly, the ground to strengthen the ground. It is best to cement the ground to avoid resonance.
5, the equipment in the use of the housing to protect the ground, the equipment casing to earth, to protect the operator and equipment operation safety.
6, after the use of the device, to turn off the system parts of the power, not charged plug power line.
7, according to the power supply voltage access equipment. Make sure the circuit is correct. Otherwise damage equipment.
8, the instrument should be placed indoors, laboratory should be clean, dry, corrosive media, non personnel do not arbitrarily operation.
9, don't let cable equipment encountered sharp edges, so as not to cut the cable insulation; don't let cable in under heavy pressure, to avoid pressure broken cable caused by fire; don't cable pull objects or objects tied with a cable, so as not to pull off the cable so that the device is not functioning properly.
10, do not let the equipment encounter water splash, corrosive gas, combustible gas and combustible material. If you don't avoid it, possibly fire..
11, devices, to cut off the power supply equipment, is to unplug the plug from the socket. No equipment or equipment moving down tilt angle of 45 degrees or above.
12, do not plug the power plug in the device when the device is running.
The characteristics of dielectric constant and dielectric loss detector:
Automatic Q \ \ the company's innovative value technology, the measuring resolution of Q to 0.1Q, the resolution to 0.00005 tan.
Can the solid insulating materials in the dielectric loss angle of 10kHz ~ 120MHz (tan delta) and Permittivity (epsilon) change test.
The tuning circuit of residual low inductance to guarantee 8nH, 100MHz (Tan d) and (E) the error is small.
The special multi parameter LCD screen menu display: Q value, frequency tuning, etc..
The Q value range automatic / manual range control.
The synthesis of DPLL 1kHz ~ 60MHz, 50kHz ~ 160MHz test signal. Independent signal source output port, so this machine is a synthetic signal source.
The test device complies with GB/T 1409-2006, ASTM D150 and IEC60250 American Standard specifications.
Dielectric constant and dielectric loss detector inductors:
According to the test frequency requirements, the need to configure the amount of inductors.
For example, when the frequency of the 1MHz test, with 250 H inductor, at the 50MHz test frequency, with 0.1 H inductor, etc..
High frequency medium sample (optional parts):
In the current high - frequency dielectric material verification system, the calibration department is the high - frequency dielectric loss meter and the measurement standard is the high - frequency standard medium sample.
The sample by artificial sapphire, quartz glass, alumina ceramics, PTFE, epoxy boards, and other materials made with diameter of 50mm, thickness 1 ~ 2mm test samples. Users can order according to the need to ensure the repeatability and accuracy of the testing device.
Range of working frequency is 10kHz ~ 120mhz, it can complete test material in the working frequency of high frequency dielectric loss angle (tan delta) and dielectric permittivity (epsilon) changes.
The instrument in the test apparatus is composed of plate capacitor and measuring cylinder linear capacitor and a parallel plate capacitor is usually used to quilt sample, equipped with the Q table as indicating instrument.
Insulating material loss angle tangent value is through the sample into the panel capacitor and not setting out the Q value of the changes in the thickness and the scale reading calculated by the formula.
Similarly, the cylindrical linear electric micrometer